{"id":15351,"date":"2026-05-20T09:00:16","date_gmt":"2026-05-20T07:00:16","guid":{"rendered":"https://www.vanderendegroup.com/es/?post_type=knowledge-base&#038;p=15351"},"modified":"2026-05-22T08:30:17","modified_gmt":"2026-05-22T06:30:17","slug":"factors-ec-value","status":"publish","type":"kennisbank","link":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/","title":{"rendered":"What factors influence the EC of reverse osmosis water?"},"content":{"rendered":"<div class=\"kb-row-layout-wrap kb-row-layout-id770_496072-e7 alignfull wp-block-kadence-rowlayout\" id=\"breadcrumbs\"><div class=\"kt-row-column-wrap kt-has-2-columns kt-row-layout-left-golden kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top kb-theme-content-width\">\n<div class=\"wp-block-kadence-column kadence-column770_1ca331-ef\"><div class=\"kt-inside-inner-col\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https://www.vanderendegroup.com/es/\">Home</a></span>  <span class=\"breadcrumb_last\" aria-current=\"page\">What factors influence the EC of reverse osmosis water?</span></span></div>\n\n<p class=\"intro-tekst wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14.642px, 0.915rem + ((1vw - 3.2px) * 0.617), 22px);letter-spacing:0.02em;line-height:1.6\">In reverse osmosis (RO), electrical conductivity (EC) is an important indicator of the purity of the produced water. A low EC indicates a very low concentration of dissolved salts. In horticulture, EC is used to monitor the nutrient content in irrigation and drainage water, while in water treatment, EC primarily provides insight into the purity of the water and the efficiency of the process. A low EC is essential in applications where accurate and stable water quality is required, such as in greenhouse horticulture and industrial process water.</p></div></div>\n\n<div class=\"wp-block-kadence-column kadence-column770_db3e8a-da kvs-md-false kvs-sm-false\"><div class=\"kt-inside-inner-col\"></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id781_0d0f4d-ff alignfull wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column781_a037d6-c4\"><div class=\"kt-inside-inner-col\"><h2 class=\"wp-block-heading\" id=\"h-heading\">What exactly is EC?</h2>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">EC stands for electrical conductivity and is a measure of the amount of dissolved salts (ions) in water. These salts make the water electrically conductive: the more dissolved salts, the higher the EC value. EC is expressed in millisiemens per centimeter (mS/cm) and is widely used to assess water quality and composition. In reverse osmosis, these salts are largely removed, giving osmosis water a very low EC, typically between 0.0 and 0.2 mS/cm.</p></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id15351_dd56fd-14 alignfull wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column15351_13d832-e3\"><div class=\"kt-inside-inner-col\"><h2 class=\"wp-block-heading\" id=\"h-what-factors-determine-the-ec-of-ro-water\">What factors determine the EC of RO water?</h2>\n\n<h3 class=\"wp-block-heading\" id=\"h-1-quality-of-the-source-water\">1. Quality of the source water</h3>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">The EC of the source water significantly determines the EC of the RO water. The higher the EC of the incoming water, the greater the amount of dissolved salts that must be removed by the RO membrane. RO membranes have a high salt rejection rate, typically between 99.2 and 99.8%, depending on the membrane type and operating conditions. As a result, highly saline or contaminated source water with a high EC can still lead to an elevated EC in the permeate.</p></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id15351_05527e-39 alignnone has-custom-blauw-grijs-background-color kt-row-has-bg wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column15351_245ac9-10\"><div class=\"kt-inside-inner-col\"><h3 class=\"wp-block-heading has-main-color has-text-color has-link-color wp-elements-1\" id=\"h-2-membrane-condition\">2. Membrane condition</h3>\n\n<p class=\"has-main-color has-text-color wp-block-paragraph\">The condition of the RO membrane has a direct impact on the EC of the osmosis water. Key factors include:</p>\n\n<h4 class=\"wp-block-heading has-main-color has-text-color has-link-color wp-elements-2\" id=\"h-scaling\">Scaling:</h4>\n\n<p class=\"has-main-color has-text-color wp-block-paragraph\">Salt deposits on the membrane surface locally increase the salt concentration, allowing more ions to pass through the permeate and raising the EC.</p>\n\n<h4 class=\"wp-block-heading has-main-color has-text-color has-link-color wp-elements-3\" id=\"h-fouling-by-colloids\">Fouling by colloids:</h4>\n\n<p class=\"has-main-color has-text-color wp-block-paragraph\">Accumulation of colloidal particles can restrict flow and increase the local salt concentration, causing the EC of the permeate to rise.</p>\n\n<h4 class=\"wp-block-heading has-main-color has-text-color has-link-color wp-elements-4\" id=\"h-chemical-damage\">Chemical damage</h4>\n\n<p class=\"has-main-color has-text-color wp-block-paragraph\">Oxidizing agents such as chlorine or ozone can reduce membrane integrity, allowing more salts to pass through the membrane and causing the EC to rise.</p>\n\n<h4 class=\"wp-block-heading has-main-color has-text-color has-link-color wp-elements-5\" id=\"h-mechanical-factors\">Mechanical factors</h4>\n\n<p class=\"has-main-color has-text-color wp-block-paragraph\">Leaking O-rings or permeate tubes can cause mixing of concentrated water with permeate, resulting in a higher EC.</p>\n\n<h4 class=\"wp-block-heading has-main-color has-text-color has-link-color wp-elements-6\" id=\"h-aging-or-wear\">Aging or wear</h4>\n\n<p class=\"has-main-color has-text-color wp-block-paragraph\">Prolonged use or normal wear can reduce membrane integrity, allowing more salts to reach the permeate and increasing the EC.</p></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id15351_57f1ee-4a alignfull wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column15351_16cf3b-1d\"><div class=\"kt-inside-inner-col\"><h3 class=\"wp-block-heading\" id=\"h-3-pressure-and-temperature\">3. Pressure and temperature</h3>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">The EC of osmosis water is influenced by the applied pressure and the temperature of the water:</p>\n\n<h4 class=\"wp-block-heading\" id=\"h-pressure\">Pressure</h4>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">Osmotic pressure is the natural pressure created when water wants to flow through a semi-permeable membrane from a low to a high salt concentration. To force water through the RO membrane and effectively remove salts, the applied pressure must be higher than this osmotic pressure. If the pressure is insufficient, the water flow through the membrane decreases, the local salt concentration at the membrane surface increases, and salt rejection may decrease, causing the EC to rise.</p>\n\n<h4 class=\"wp-block-heading\" id=\"h-temperature\">Temperature</h4>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">Electrical conductivity increases at higher temperatures because ions are more mobile than at lower temperatures. Therefore, EC is often reported at 25°C. At varying temperatures, the measured EC may temporarily differ, while the actual amount of dissolved salts remains unchanged. At higher temperatures, water becomes less dense, increasing the flow rate through the membrane, but at the same time, selectivity (rejection) decreases slightly. This can lead to a higher EC in the permeate.</p></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id15351_601967-f1 alignfull wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column15351_ec95e7-52\"><div class=\"kt-inside-inner-col\"><h3 class=\"wp-block-heading\" id=\"h-4-recovery-setting\">4. Recovery setting</h3>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">The recovery setting of an RO system determines how much permeate water is produced from the source water. At a higher recovery rate, less wastewater is produced and the production of osmosis water increases. At the same time, the salt concentration in the concentrate increases, widening the difference in salt concentration between the concentrate and the permeate. This concentration difference acts as a driving force that causes some dissolved salts to pass through the membrane despite the fact that the membrane blocks most salts. As a result, the EC in the osmosis water may increase.</p></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id15351_c5bff0-9b alignfull wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column15351_d15eb2-72\"><div class=\"kt-inside-inner-col\"><h2 class=\"wp-block-heading\" id=\"h-when-should-you-take-action\">When should you take action?</h2>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">A rising EC in RO water can be an indication of one or more of the following problems:</p>\n\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items15351_208e7d-fe kt-svg-icon-list-columns-1 alignnone\"><ul class=\"kt-svg-icon-list\"><li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-15351_3c7f82-b1\"><span class=\"kb-svg-icon-wrap kb-svg-icon-kb-custom-1300 kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"currentColor\" xmlns=\"http://www.w3.org/2000/svg\"  aria-hidden=\"true\"><path d=\"M18.5796 11.6263C18.8033 11.8252 18.8033 12.1748 18.5796 12.3737L6.33218 23.2603C6.00973 23.5469 5.5 23.318 5.5 22.8866L5.5 1.11342C5.5 0.681998 6.00973 0.453095 6.33218 0.739717L18.5796 11.6263Z\"/></svg></span><span class=\"kt-svg-icon-list-text\">Incipient membrane fouling</span></li>\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-15351_2bf582-2b\"><span class=\"kb-svg-icon-wrap kb-svg-icon-kb-custom-1300 kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"currentColor\" xmlns=\"http://www.w3.org/2000/svg\"  aria-hidden=\"true\"><path d=\"M18.5796 11.6263C18.8033 11.8252 18.8033 12.1748 18.5796 12.3737L6.33218 23.2603C6.00973 23.5469 5.5 23.318 5.5 22.8866L5.5 1.11342C5.5 0.681998 6.00973 0.453095 6.33218 0.739717L18.5796 11.6263Z\"/></svg></span><span class=\"kt-svg-icon-list-text\">Chemical or mechanical damage</span></li>\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-15351_48b517-56\"><span class=\"kb-svg-icon-wrap kb-svg-icon-kb-custom-1300 kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"currentColor\" xmlns=\"http://www.w3.org/2000/svg\"  aria-hidden=\"true\"><path d=\"M18.5796 11.6263C18.8033 11.8252 18.8033 12.1748 18.5796 12.3737L6.33218 23.2603C6.00973 23.5469 5.5 23.318 5.5 22.8866L5.5 1.11342C5.5 0.681998 6.00973 0.453095 6.33218 0.739717L18.5796 11.6263Z\"/></svg></span><span class=\"kt-svg-icon-list-text\">Aged membranes</span></li>\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-15351_a097ab-34\"><span class=\"kb-svg-icon-wrap kb-svg-icon-kb-custom-1300 kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"currentColor\" xmlns=\"http://www.w3.org/2000/svg\"  aria-hidden=\"true\"><path d=\"M18.5796 11.6263C18.8033 11.8252 18.8033 12.1748 18.5796 12.3737L6.33218 23.2603C6.00973 23.5469 5.5 23.318 5.5 22.8866L5.5 1.11342C5.5 0.681998 6.00973 0.453095 6.33218 0.739717L18.5796 11.6263Z\"/></svg></span><span class=\"kt-svg-icon-list-text\">Recovery settings set too high</span></li>\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-15351_968afa-12\"><span class=\"kb-svg-icon-wrap kb-svg-icon-kb-custom-1300 kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"currentColor\" xmlns=\"http://www.w3.org/2000/svg\"  aria-hidden=\"true\"><path d=\"M18.5796 11.6263C18.8033 11.8252 18.8033 12.1748 18.5796 12.3737L6.33218 23.2603C6.00973 23.5469 5.5 23.318 5.5 22.8866L5.5 1.11342C5.5 0.681998 6.00973 0.453095 6.33218 0.739717L18.5796 11.6263Z\"/></svg></span><span class=\"kt-svg-icon-list-text\">Imbalance in pressure or flow</span></li></ul></div>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">It is advisable to actively monitor EC trends in the RO water so that incipient fouling or process deviations are detected early and maintenance can be performed in a timely manner. </p></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id15351_e066ef-92 alignfull wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column15351_c1274b-25\"><div class=\"kt-inside-inner-col\"><h2 class=\"wp-block-heading\" id=\"h-how-does-monitoring-help-with-this\">How does monitoring help with this?</h2>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">A platform such as<a href=\"https://www.vanderendegroup.com/es/product/hydropatrol/\"> HydroPatrol </a>provides real-time insight into the water quality, pressure, flow, and membrane condition of reverse osmosis systems. Through automatic alerts and trend analysis, deviations can be detected early, preventing downtime or membrane failure and allowing maintenance to be scheduled in a timely manner.</p></div></div>\n</div></div><div class=\"kb-row-layout-wrap kb-row-layout-id781_0d0f4d-ff alignfull wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<div class=\"wp-block-kadence-column kadence-column781_a037d6-c4\"><div class=\"kt-inside-inner-col\"><h2 class=\"wp-block-heading\" id=\"h-heading\">Want to know more?</h2>\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.336), 18px);\">Every application requires a tailored solution. Is your question not addressed in this article, or would you like to discuss your specific situation? Please <a href=\"https://www.vanderendegroup.com/es/contact/\">contact</a> one of our specialists. We are happy to assist you with expert advice and practical support.</p></div></div>\n</div></div>","protected":false},"author":5,"featured_media":15336,"template":"","meta":{"_acf_changed":false,"_searchwp_excluded":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","editor_notices":[],"footnotes":""},"class_list":["post-15351","kennisbank","type-kennisbank","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.3 (Yoast SEO v28.7) - https://yoast.com/product/yoast-seo-premium-wordpress/ -->\n<title>What factors influence the EC of reverse osmosis water? - Van der Ende Group</title>\n<meta name=\"robots\" content=\"noindex, follow\" />\n<meta property=\"og:locale\" content=\"es_ES\" />\n<meta property=\"og:type\" content=\"article\" />\n<meta property=\"og:title\" content=\"What factors influence the EC of reverse osmosis water?\" />\n<meta property=\"og:description\" content=\"What factors determine the EC of RO water? 1. Quality of the source water The EC of the source water significantly determines the EC of the RO water. The higher the EC of the incoming water, the greater the amount of dissolved salts that must be removed by the RO membrane. RO membranes have a [&hellip;]\" />\n<meta property=\"og:url\" content=\"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/\" />\n<meta property=\"og:site_name\" content=\"Van der Ende Group\" />\n<meta property=\"article:modified_time\" content=\"2026-05-22T06:30:17+00:00\" />\n<meta property=\"og:image\" content=\"https://www.vanderendegroup.com/wp-content/uploads/sites/3/2026/05/recovery-V2-EN.png\" />\n\t<meta property=\"og:image:width\" content=\"900\" />\n\t<meta property=\"og:image:height\" content=\"600\" />\n\t<meta property=\"og:image:type\" content=\"image/png\" />\n<meta name=\"twitter:card\" content=\"summary_large_image\" />\n<meta name=\"twitter:label1\" content=\"Est. reading time\" />\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" />\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\/\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/\",\"url\":\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/\",\"name\":\"What factors influence the EC of reverse osmosis water? - Van der Ende Group\",\"isPartOf\":{\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\/\\/www.vanderendegroup.com\\/wp-content\\/uploads\\/sites\\/3\\/2026\\/05\\/recovery-V2-EN.png\",\"datePublished\":\"2026-05-20T07:00:16+00:00\",\"dateModified\":\"2026-05-22T06:30:17+00:00\",\"breadcrumb\":{\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/#breadcrumb\"},\"inLanguage\":\"es-ES\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-ES\",\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/#primaryimage\",\"url\":\"https:\\/\\/www.vanderendegroup.com\\/wp-content\\/uploads\\/sites\\/3\\/2026\\/05\\/recovery-V2-EN.png\",\"contentUrl\":\"https:\\/\\/www.vanderendegroup.com\\/wp-content\\/uploads\\/sites\\/3\\/2026\\/05\\/recovery-V2-EN.png\",\"width\":900,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/knowledge-center\\/factors-ec-value\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\/\\/www.vanderendegroup.com\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What factors influence the EC of reverse osmosis water?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/#website\",\"url\":\"https:\\/\\/www.vanderendegroup.com\\/\",\"name\":\"Van der Ende Group\",\"description\":\"Innovator, producent en leverancier van technische producten\",\"publisher\":{\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\/\\/www.vanderendegroup.com\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-ES\"},{\"@type\":\"Organization\",\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/#organization\",\"name\":\"Van der Ende Group\",\"url\":\"https:\\/\\/www.vanderendegroup.com\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-ES\",\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/#\\/schema\\/logo\\/image\\/\",\"url\":\"https:\\/\\/www.vanderendegroup.com\\/wp-content\\/uploads\\/sites\\/3\\/2024\\/09\\/favicon-500x500px.png\",\"contentUrl\":\"https:\\/\\/www.vanderendegroup.com\\/wp-content\\/uploads\\/sites\\/3\\/2024\\/09\\/favicon-500x500px.png\",\"width\":500,\"height\":500,\"caption\":\"Van der Ende Group\"},\"image\":{\"@id\":\"https:\\/\\/www.vanderendegroup.com\\/#\\/schema\\/logo\\/image\\/\"}}]}</script>\n<!-- / Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"¿Qué factores influyen en la CE del agua de ósmosis inversa? - Van der Ende Group","robots":{"index":"noindex","follow":"follow"},"og_locale":"es_ES","og_type":"article","og_title":"What factors influence the EC of reverse osmosis water?","og_description":"What factors determine the EC of RO water? 1. Quality of the source water The EC of the source water significantly determines the EC of the RO water. The higher the EC of the incoming water, the greater the amount of dissolved salts that must be removed by the RO membrane. RO membranes have a [&hellip;]","og_url":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/","og_site_name":"Van der Ende Group","article_modified_time":"2026-05-22T06:30:17+00:00","og_image":[{"width":900,"height":600,"url":"https://www.vanderendegroup.com/wp-content/uploads/sites/3/2026/05/recovery-V2-EN.png","type":"image/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"WebPage","@id":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/","url":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/","name":"What factors influence the EC of reverse osmosis water? - Van der Ende Group","isPartOf":{"@id":"https://www.vanderendegroup.com/es/#website"},"primaryImageOfPage":{"@id":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/#primaryimage"},"image":{"@id":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/#primaryimage"},"thumbnailUrl":"https://www.vanderendegroup.com/wp-content/uploads/sites/3/2026/05/recovery-V2-EN.png","datePublished":"2026-05-20T07:00:16+00:00","dateModified":"2026-05-22T06:30:17+00:00","breadcrumb":{"@id":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/#breadcrumb"},"inLanguage":"es-ES","potentialAction":[{"@type":"ReadAction","target":["https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/"]}]},{"@type":"ImageObject","inLanguage":"es-ES","@id":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/#primaryimage","url":"https://www.vanderendegroup.com/wp-content/uploads/sites/3/2026/05/recovery-V2-EN.png","contentUrl":"https://www.vanderendegroup.com/wp-content/uploads/sites/3/2026/05/recovery-V2-EN.png","width":900,"height":600},{"@type":"BreadcrumbList","@id":"https://www.vanderendegroup.com/es/knowledge-center/factors-ec-value/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.vanderendegroup.com/es/"},{"@type":"ListItem","position":2,"name":"What factors influence the EC of reverse osmosis water?"}]},{"@type":"WebSite","@id":"https://www.vanderendegroup.com/es/#website","url":"https://www.vanderendegroup.com/es/","name":"Van der Ende Group","description":"Innovator, producent en leverancier van technische producten","publisher":{"@id":"https://www.vanderendegroup.com/es/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.vanderendegroup.com/es/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-ES"},{"@type":"Organization","@id":"https://www.vanderendegroup.com/es/#organization","name":"Van der Ende Group","url":"https://www.vanderendegroup.com/es/","logo":{"@type":"ImageObject","inLanguage":"es-ES","@id":"https://www.vanderendegroup.com/es/#/schema/logo/image/","url":"https://www.vanderendegroup.com/wp-content/uploads/sites/3/2024/09/favicon-500x500px.png","contentUrl":"https://www.vanderendegroup.com/wp-content/uploads/sites/3/2024/09/favicon-500x500px.png","width":500,"height":500,"caption":"Van der Ende Group"},"image":{"@id":"https://www.vanderendegroup.com/es/#/schema/logo/image/"}}]}},"taxonomy_info":[],"featured_image_src_large":["https://www.vanderendegroup.com/wp-content/uploads/sites/3/2026/05/recovery-V2-EN.png",900,600,false],"author_info":{"display_name":"markvanderende","author_link":"https://www.vanderendegroup.com/es/author/markvanderende/"},"comment_info":"","permalink_manager":null,"_links":{"self":[{"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/kennisbank/15351","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/kennisbank"}],"about":[{"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/types/kennisbank"}],"author":[{"embeddable":true,"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/users/5"}],"version-history":[{"count":2,"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/kennisbank/15351/revisions"}],"predecessor-version":[{"id":15446,"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/kennisbank/15351/revisions/15446"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/media/15336"}],"wp:attachment":[{"href":"https://www.vanderendegroup.com/es/wp-json/wp/v2/media?parent=15351"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}